
24
8.4.1.4 Communication Malfunction (E6)
1. Check if connection wire between indoor and outdoor units and wire inside the unit are connected well.
2. Check if mainboard of indoor or outdoor unit is damaged.
Communication malfunction of indoor unit
Power off the unit and check if the connecting
wire of indoor and outdoor unit and wiring o
electric box are correct.
Is wire connected correctly?
Does the broken-down indoor unit resume normal?
Replace the broken-down mainboard of the indoor unit
End
Connect wires according
to the wiring diagram
Is malfunction removed?
Power off the unit. Change the communication cable o
indoor units. Energize the unit and wait for 3 min
Replace mainboard of outdoor unit
No
Yes
Yes
Yes
Kommentare zu diesen Handbüchern